Installation Guide
Tools Needed:
- Adjustable wrench
- Level
- Screwdrivers (flat and Phillips)
- Drill with hole saw
- Tape measure
- Vacuum pump
- Manifold gauge set
Step-by-Step Installation
- Choose Installation Location: Select a location with proper wall support, away from direct sunlight and heat sources, with adequate clearance for airflow.
- Install Mounting Bracket: Secure the mounting bracket to the wall using appropriate anchors and ensure it is perfectly level.
- Drill Hole for Pipes: Drill a 70mm hole through the wall for refrigerant pipes, drainage hose, and electrical cables.
- Connect Refrigerant Pipes: Connect the indoor and outdoor unit pipes, ensuring tight connections and proper insulation.
- Connect Drainage Hose: Route the drainage hose with a downward slope to ensure proper water drainage.
- Electrical Connection: Connect to a dedicated 220-240V, 50Hz circuit with proper grounding. Follow local electrical codes.
- Vacuum and Charge: Evacuate air from refrigerant lines using a vacuum pump, then charge with specified refrigerant amount.
- Test Run: Run the air conditioner in cooling mode to check for proper operation, cooling performance, and drainage.
Specifications
| Model Series | BW-AC12000INV |
| Type | Split Type Air Conditioner |
| Color | White / Silver |
| Cooling Capacity | 12000 BTU/h (3.5 kW) |
| Heating Capacity | 13000 BTU/h (3.8 kW) |
| Noise Level (Indoor) | 19-38 dB |
| Control Type | Digital Display with Remote Control |
| Energy Rating | A++ (Energy Efficient) |
| Power Consumption (Cooling) | 1050 W |
| Power Requirements | 220-240V, 50Hz, 15A |
| Refrigerant | R32 (Eco-friendly) |
| Dimensions Indoor (HxWxD) | 29 x 80 x 19 cm |
| Dimensions Outdoor (HxWxD) | 55 x 80 x 28 cm |
| Weight Indoor/Outdoor | 9 kg / 28 kg |
| Air Flow (Max) | 600 m³/h |
Warranty Information
- Full Warranty: 1 year comprehensive warranty
- Compressor Warranty: 5 years on inverter compressor
- PCB Warranty: 2 years on printed circuit board
- Additional Coverage: Optional extended warranty available
For warranty service, contact Blueway Customer Service at 1-800-555-BLUE or visit Blueway.com
Key Features
Inverter Technology
Advanced inverter compressor adjusts cooling/heating power based on room temperature, maintaining consistent comfort while reducing energy consumption by up to 40%.
4D Auto Swing
Automatic vertical and horizontal louvers movement ensures even air distribution throughout the room, eliminating hot/cold spots.
Turbo Cooling/Heating
Rapid cooling/heating function quickly reaches desired temperature, perfect for immediate comfort when entering a room.
Sleep Mode
Intelligent sleep mode automatically adjusts temperature and fan speed throughout the night for optimal sleeping conditions and energy savings.
Self-Cleaning Function
Automatically cleans the indoor unit's heat exchanger to prevent mold and bacteria growth, ensuring healthy air quality.
Wi-Fi Smart Control
Connect to home Wi-Fi for remote control via smartphone app, allowing scheduling, monitoring, and control from anywhere.
Operating Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature and fan speed settings
Heat Mode
Heating operation for cold weather with automatic defrost cycle
Dry Mode
Dehumidification function that removes excess moisture without overcooling
Fan Mode
Circulates air without cooling or heating, with multiple fan speed options
Auto Mode
Intelligent mode that automatically selects cooling or heating based on room temperature
Eco Mode
Energy-saving operation that optimizes performance for maximum efficiency
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| AC won't turn on | Power issue, remote control batteries dead, circuit breaker tripped | Check power supply, replace remote batteries, reset circuit breaker |
| Poor cooling/heating | Dirty filters, low refrigerant, outdoor unit blocked | Clean filters, check for refrigerant leak, clear outdoor unit area |
| Water leaking indoors | Clogged drain pipe, improper installation slope | Clean drain pipe, ensure proper downward slope |
| Unusual noises | Loose parts, debris in fan, vibrating pipes | Tighten all components, clean fan blades, secure pipe insulation |
| Foul odor | Dirty filters, mold growth in indoor unit | Clean/replace filters, run self-cleaning function |
| Remote not working | Batteries dead, signal blocked, sensor issue | Replace batteries, ensure line of sight, check indoor unit sensor |
Error Codes
- E1: Room temperature sensor error - Check sensor connection
- E2: Pipe temperature sensor error - Check sensor connection
- E3: Communication error - Check wiring between indoor/outdoor units
- E4: High pressure protection - Check outdoor unit ventilation
- E5: Low pressure protection - Check for refrigerant leak
- E6: Compressor overload - Wait 3 minutes and restart
- E7: Fan motor error - Check fan motor and blades
- E8: Water full protection - Empty drainage tank
Manual Downloads
Current Model Manuals
BW-AC12000INV
12000 BTU Inverter AC
BW-AC18000INV
18000 BTU Inverter AC
BW-AC9000INV
9000 BTU Inverter AC
BW-AC24000INV
24000 BTU Inverter AC
Popular Previous Models
BW-AC12000STD
12000 BTU Standard AC
BW-AC18000STD
18000 BTU Standard AC
BW-AC9000WIN
9000 BTU Window AC
BW-AC12000WIN