Blueway Air Conditioner

User Manual & Installation Guide

12000 BTU Capacity

Installation Guide

Tools Needed:

  • Adjustable wrench
  • Level
  • Screwdrivers (flat and Phillips)
  • Drill with hole saw
  • Tape measure
  • Vacuum pump
  • Manifold gauge set

Step-by-Step Installation

  1. Choose Installation Location: Select a location with proper wall support, away from direct sunlight and heat sources, with adequate clearance for airflow.
  2. Install Mounting Bracket: Secure the mounting bracket to the wall using appropriate anchors and ensure it is perfectly level.
  3. Drill Hole for Pipes: Drill a 70mm hole through the wall for refrigerant pipes, drainage hose, and electrical cables.
  4. Connect Refrigerant Pipes: Connect the indoor and outdoor unit pipes, ensuring tight connections and proper insulation.
  5. Connect Drainage Hose: Route the drainage hose with a downward slope to ensure proper water drainage.
  6. Electrical Connection: Connect to a dedicated 220-240V, 50Hz circuit with proper grounding. Follow local electrical codes.
  7. Vacuum and Charge: Evacuate air from refrigerant lines using a vacuum pump, then charge with specified refrigerant amount.
  8. Test Run: Run the air conditioner in cooling mode to check for proper operation, cooling performance, and drainage.
Warning: Installation must be performed by a certified HVAC technician. DIY installation may void warranty and create safety hazards.

Specifications

Model Series BW-AC12000INV
Type Split Type Air Conditioner
Color White / Silver
Cooling Capacity 12000 BTU/h (3.5 kW)
Heating Capacity 13000 BTU/h (3.8 kW)
Noise Level (Indoor) 19-38 dB
Control Type Digital Display with Remote Control
Energy Rating A++ (Energy Efficient)
Power Consumption (Cooling) 1050 W
Power Requirements 220-240V, 50Hz, 15A
Refrigerant R32 (Eco-friendly)
Dimensions Indoor (HxWxD) 29 x 80 x 19 cm
Dimensions Outdoor (HxWxD) 55 x 80 x 28 cm
Weight Indoor/Outdoor 9 kg / 28 kg
Air Flow (Max) 600 m³/h

Warranty Information

  • Full Warranty: 1 year comprehensive warranty
  • Compressor Warranty: 5 years on inverter compressor
  • PCB Warranty: 2 years on printed circuit board
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Blueway Customer Service at 1-800-555-BLUE or visit Blueway.com

Key Features

Inverter Technology

Advanced inverter compressor adjusts cooling/heating power based on room temperature, maintaining consistent comfort while reducing energy consumption by up to 40%.

4D Auto Swing

Automatic vertical and horizontal louvers movement ensures even air distribution throughout the room, eliminating hot/cold spots.

Turbo Cooling/Heating

Rapid cooling/heating function quickly reaches desired temperature, perfect for immediate comfort when entering a room.

Sleep Mode

Intelligent sleep mode automatically adjusts temperature and fan speed throughout the night for optimal sleeping conditions and energy savings.

Self-Cleaning Function

Automatically cleans the indoor unit's heat exchanger to prevent mold and bacteria growth, ensuring healthy air quality.

Wi-Fi Smart Control

Connect to home Wi-Fi for remote control via smartphone app, allowing scheduling, monitoring, and control from anywhere.

Operating Modes Explained

Cool Mode

Standard cooling operation with adjustable temperature and fan speed settings

Heat Mode

Heating operation for cold weather with automatic defrost cycle

Dry Mode

Dehumidification function that removes excess moisture without overcooling

Fan Mode

Circulates air without cooling or heating, with multiple fan speed options

Auto Mode

Intelligent mode that automatically selects cooling or heating based on room temperature

Eco Mode

Energy-saving operation that optimizes performance for maximum efficiency

Troubleshooting

Problem Possible Cause Solution
AC won't turn on Power issue, remote control batteries dead, circuit breaker tripped Check power supply, replace remote batteries, reset circuit breaker
Poor cooling/heating Dirty filters, low refrigerant, outdoor unit blocked Clean filters, check for refrigerant leak, clear outdoor unit area
Water leaking indoors Clogged drain pipe, improper installation slope Clean drain pipe, ensure proper downward slope
Unusual noises Loose parts, debris in fan, vibrating pipes Tighten all components, clean fan blades, secure pipe insulation
Foul odor Dirty filters, mold growth in indoor unit Clean/replace filters, run self-cleaning function
Remote not working Batteries dead, signal blocked, sensor issue Replace batteries, ensure line of sight, check indoor unit sensor

Error Codes

  • E1: Room temperature sensor error - Check sensor connection
  • E2: Pipe temperature sensor error - Check sensor connection
  • E3: Communication error - Check wiring between indoor/outdoor units
  • E4: High pressure protection - Check outdoor unit ventilation
  • E5: Low pressure protection - Check for refrigerant leak
  • E6: Compressor overload - Wait 3 minutes and restart
  • E7: Fan motor error - Check fan motor and blades
  • E8: Water full protection - Empty drainage tank

Manual Downloads

Current Model Manuals

BW-AC12000INV

12000 BTU Inverter AC

BW-AC18000INV

18000 BTU Inverter AC

BW-AC9000INV

9000 BTU Inverter AC

BW-AC24000INV

24000 BTU Inverter AC

Popular Previous Models

BW-AC12000STD

12000 BTU Standard AC

BW-AC18000STD

18000 BTU Standard AC

BW-AC9000WIN

9000 BTU Window AC

BW-AC12000WIN

12000 BTU Window AC

Note: For models not listed here, please visit the Blueway Support Website for complete documentation.