Installation Guide
Tools Needed:
- Adjustable wrench set
- Level
- Screwdrivers (flat and Phillips)
- Pipe wrench
- Tape measure
- Safety glasses and gloves
Step-by-Step Installation
- Choose Installation Location: Select a well-ventilated area on a solid, level concrete floor with adequate clearance for maintenance.
- Unpack and Inspect: Remove all packaging materials and inspect for shipping damage. Check oil level in pump.
- Position the Compressor: Place compressor in desired location, ensuring it's level using shims if necessary.
- Electrical Connection: Connect to a dedicated 240V, 60Hz circuit with proper grounding. Consult local electrical codes.
- Air System Setup: Install air filter on intake, connect air lines using appropriate fittings, and install pressure regulator.
- Drain Installation: Connect drain line to tank drain valve and route to appropriate drainage location.
- Initial Startup: Open tank drain valve, turn on power, allow compressor to build pressure, then check for leaks.
Specifications
| Model Series | CMAF060T |
| Type | Vertical Tank Air Compressor |
| Color | Black/Red |
| Tank Capacity | 60 Gallons |
| Noise Level | 78 dB |
| Control Type | Pressure Switch with Magnetic Starter |
| Motor Type | 5 HP, 240V Single Phase |
| Air Delivery | 15.1 CFM @ 90 PSI |
| Max Pressure | 155 PSI |
| Power Requirements | 240V, 60Hz, 21A |
| Dimensions (HxWxD) | 72 x 24 x 30 inches |
| Weight | 285 lbs |
| Pump Type | Two-Stage Cast Iron |
Warranty Information
- Full Warranty: 2 years parts and labor
- Tank Warranty: Lifetime limited warranty
- Pump Warranty: 3 years
- Additional Coverage: Optional extended warranty available
For warranty service, contact Craftsman Customer Service at 1-888-331-4569 or visit Craftsman.com
Key Features
Two-Stage Pump
High-efficiency two-stage pump provides greater air delivery and cooler operation for extended tool run time and longer pump life.
ASME Certified Tank
60-gallon ASME certified tank with lifetime warranty provides ample air storage for continuous operation of multiple tools.
Magnetic Starter
Industrial-grade magnetic starter with overload protection ensures reliable motor starting and protection against voltage fluctuations.
Low Oil Shutdown
Automatic shutdown feature protects the pump from damage if oil level becomes too low during operation.
Thermal Overload Protection
Built-in thermal protection prevents motor damage from overheating during extended use or high ambient temperatures.
Easy Drain System
Convenient tank drain valve allows for easy moisture removal to prevent tank corrosion and maintain air quality.
Performance Specifications
Air Tools
Can power up to 3 average air tools simultaneously
Recovery Time
90 PSI recovery in 2 minutes 45 seconds from empty
Duty Cycle
75% duty cycle for continuous industrial use
Oil Capacity
64 oz synthetic compressor oil capacity
Outlet Configuration
Two 1/2" NPT outlets with quick-connect fittings
Pressure Gauge
Dual gauges for tank pressure and regulated pressure
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor won't start | Power issue, pressure switch fault, thermal overload tripped | Check power supply, reset thermal overload, check pressure switch |
| Low air pressure | Air leaks, worn pump rings, clogged air filter | Check for leaks, inspect pump, clean or replace air filter |
| Excessive noise/vibration | Loose components, worn bearings, improper mounting | Tighten all fasteners, check bearings, ensure proper installation |
| Oil in air lines | Overfilled oil, worn piston rings, incorrect oil type | Check oil level, inspect pump, use recommended synthetic oil |
| Motor overheating | Low voltage, restricted ventilation, excessive cycling | Check voltage, ensure proper clearance, adjust pressure switch |
| Slow pressure buildup | Worn valves, leaking check valve, intake restriction | Inspect pump valves, check check valve, clean intake |
Maintenance Codes & Indicators
- Red Oil Light: Low oil level - Check and add oil immediately
- Thermal Overload Trip: Motor overheated - Allow to cool, check ventilation
- Pressure Switch Clicking: Normal operation during pressure cycling
- Unusual Knocking: Worn bearings or connecting rod - Service required
- Excessive Moisture: Drain tank more frequently, check air dryer
- Oil Leaks: Check gaskets, seals, and drain plug
Manual Downloads
Current Model Manuals
CMAF060T
60 Gallon Vertical Air Compressor
CMAF080T
80 Gallon Two-Stage Compressor
CMAP060V
60 Gallon Portable Compressor
CMAF060S
60 Gallon Silent Series
Popular Previous Models
919.167380
60 Gallon Professional Series
919.152231
60 Gallon Industrial Compressor
919.168380
60 Gallon Belt Drive
919.145221
60 Gallon Single Stage