Craftsman Air Compressor Parts Manual

User Manual & Parts Catalog

Professional Series

Installation Guide

Tools Needed:

  • Adjustable wrench set
  • Socket set
  • Screwdrivers (flat and Phillips)
  • Pressure gauge
  • Level

Step-by-Step Installation

  1. Choose Installation Location: Select a clean, dry, well-ventilated area with solid, level flooring and adequate clearance for maintenance.
  2. Unpack and Inspect: Remove all packaging materials and inspect for shipping damage. Verify all parts are included.
  3. Position Compressor: Place compressor on a stable surface, ensuring it's level to prevent oil migration and vibration issues.
  4. Electrical Connection: Connect to a properly grounded 120V/240V outlet as specified for your model. Use appropriate circuit breaker.
  5. Air System Setup: Install air filter on intake, connect air hose using appropriate fittings, and install pressure regulator if included.
  6. Oil Check: Verify oil level in pump (if oil-lubricated model) and add recommended compressor oil if necessary.
  7. Initial Test Run: Run compressor without load for 10-15 minutes to break in components, then check for leaks and proper pressure buildup.
Warning: All installations must be performed by qualified personnel. Ensure proper ventilation and follow all local electrical codes.

Specifications

Model Series CMXECXA0710047
Type Stationary Air Compressor
Horsepower 5.0 HP
Tank Capacity 60 Gallon
Max Pressure 175 PSI
CFM at 90 PSI 15.5 CFM
CFM at 40 PSI 18.5 CFM
Pump Type Two-Stage Cast Iron
Motor Type TEFC Induction Motor
Voltage Requirements 230V, 60Hz, Single Phase
Dimensions (HxWxD) 65 x 30 x 30 inches
Weight 325 lbs
Sound Level 78 dB

Warranty Information

  • Full Warranty: 2 years parts and labor
  • Pump Warranty: 5 years limited warranty
  • Tank Warranty: Lifetime limited warranty
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Craftsman Customer Service at 1-888-331-4569 or visit Craftsman.com

Key Features

Two-Stage Pump System

Advanced two-stage compression provides higher efficiency, cooler operation, and longer pump life compared to single-stage compressors.

Cast Iron Construction

Heavy-duty cast iron pump cylinders and components ensure durability, better heat dissipation, and reduced vibration during operation.

ASME Certified Tank

60-gallon ASME certified air tank with automatic drain valve provides reliable storage and meets industry safety standards.

Magnetic Starter

Built-in magnetic starter with overload protection prevents motor damage from voltage fluctuations and excessive current draw.

Pressure Control System

Precision pressure switch with adjustable cut-in/cut-out settings and built-in unloader valve for consistent pressure delivery.

Thermal Overload Protection

Integrated thermal protection automatically shuts down the motor if overheating is detected, preventing damage to windings and components.

Pump System Components

First Stage Cylinder

Low-pressure compression chamber with intake valve and piston assembly

Intercooler

Heat exchanger between stages that cools air for more efficient second-stage compression

Second Stage Cylinder

High-pressure compression chamber with discharge valve assembly

Check Valve

Prevents backflow from tank to pump during shutdown and between cycles

Pressure Relief Valve

Safety device that automatically releases pressure if system exceeds maximum rating

Oil System

Forced lubrication system with sight glass and dipstick for proper oil level monitoring

Troubleshooting

Problem Possible Cause Solution
Compressor won't start Power issue, pressure switch fault, thermal overload tripped Check power supply, reset overload, test pressure switch contacts
Low pressure output Worn piston rings, leaking valves, intake filter clogged Check compression, inspect valves, clean or replace air filter
Excessive noise/vibration Loose mounting bolts, worn bearings, piston slap Tighten all fasteners, check bearings, inspect cylinder wear
Oil in air lines Worn piston rings, overfilled oil, wrong oil type Check oil level and type, inspect rings and cylinder
Motor overheats Low voltage, restricted ventilation, excessive cycling Check voltage, ensure proper clearance, adjust pressure settings
Continuous running Air leak, faulty pressure switch, check valve failure Check for leaks, test pressure switch, inspect check valve

Common Error Indicators

  • Red Overload Light: Motor thermal overload - Allow cool down, check ventilation
  • Low Pressure Warning: System below minimum pressure - Check pump, valves, and seals
  • Oil Alert: Low oil level or pressure - Check oil level and pump lubrication
  • High Temp Warning: System overheating - Check cooling fins, ventilation, ambient temperature
  • Pressure Switch Fault: Switch not activating properly - Test switch contacts and adjustment
  • Motor Fault: Electrical issue with motor - Check connections, capacitors, and windings

Manual Downloads

Current Model Manuals

CMXECXA0710047

5HP 60-Gallon Two-Stage

CMXECXA0610046

4HP 30-Gallon Vertical

CMXECXA0510045

3HP 20-Gallon Portable

CMXECXA0410044

6HP 80-Gallon Industrial

Popular Previous Models

919167380

3.5HP 30-Gallon Oil-Free

919152231

4HP 60-Gallon Single Stage

919146541

2HP 20-Gallon Pancake

919138320

1.5HP 6-Gallon Hot Dog

Note: For models not listed here, please visit the Craftsman Support Website for complete documentation and parts diagrams.