Installation Guide
Tools Needed:
- Phillips screwdriver
- Wall anchors (if not included)
- Level
- Drill with appropriate bits
- Measuring tape
- Pencil for marking
Step-by-Step Installation
- Choose Installation Location: Select a location on an interior wall, approximately 1.5 meters above floor level, away from direct sunlight and heat sources.
- Prepare Mounting Area: Ensure the wall is clean, dry, and structurally sound. Avoid mounting on walls with excessive vibration.
- Mount Backplate: Use the provided template to mark screw positions. Drill holes and insert wall anchors if needed. Secure the backplate to the wall.
- Connect Wiring: Connect the control panel wires to the corresponding terminals on the indoor unit following the wiring diagram provided.
- Attach Control Panel: Align the control panel with the backplate and snap into place. Ensure all connections are secure.
- Power Connection: Ensure main power to the air conditioning system is turned off during installation. Restore power after installation is complete.
- Test Operation: Turn on the system and test all functions including temperature control, mode selection, and fan speed settings.
Specifications
| Model Series | BRC1E63 / BRC1E52 |
| Type | Wireless Remote Controller |
| Color | White / Silver |
| Display Type | LCD with Backlight |
| Control Range | Up to 8 meters |
| Power Source | 2 x AAA Batteries (included) |
| Battery Life | Approximately 1 year (normal use) |
| Operating Temperature | 0°C to 50°C |
| Dimensions (HxWxD) | 85 x 60 x 20 mm |
| Weight | 95 g (including batteries) |
| Compatible Models | FTXS, ATXS, CTXS Series |
| Communication | Infrared Wireless |
Warranty Information
- Full Warranty: 1 year parts and labor
- Extended Coverage: 5 years on compressor when registered
- Additional Coverage: Optional extended warranty available
For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com
Key Features
Intelligent Eye
Built-in motion sensor detects human presence and adjusts operation to save energy when the room is unoccupied, automatically resuming comfort settings when movement is detected.
Coanda Airflow
Advanced airflow control that spreads cool air along the ceiling for even temperature distribution without direct drafts, providing uniform comfort throughout the room.
Powerful Operation
Turbo mode provides rapid cooling or heating to reach desired temperature quickly, then automatically switches to normal operation for energy efficiency.
Quiet Operation
Night mode reduces operating noise to as low as 19 dB, ensuring undisturbed sleep while maintaining comfortable temperature settings.
3D Airflow
Adjustable vertical and horizontal louvers allow precise control of air direction, enabling customized comfort for any room layout.
Self-Clean Operation
Automatically dries the indoor unit after use to prevent mold and bacteria growth, maintaining air quality and reducing maintenance needs.
Operation Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature settings from 16°C to 30°C
Heat Mode
Heating operation with temperature range from 16°C to 30°C for winter comfort
Dry Mode
Dehumidification function that removes excess moisture while maintaining room temperature
Fan Mode
Air circulation without cooling or heating, with multiple fan speed options
Auto Mode
Intelligent mode that automatically selects cooling or heating based on room temperature
Night Mode
Quiet operation with gradual temperature adjustment for sleeping comfort
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Control panel not responding | Dead batteries, signal obstruction, out of range | Replace batteries, ensure clear line of sight, move closer to indoor unit |
| Unit not cooling/heating | Wrong mode selected, temperature setting incorrect, filter dirty | Select correct mode, adjust temperature setting, clean air filter |
| Display blank or dim | Batteries low, backlight timeout, display issue | Replace batteries, press any button to activate, check battery contacts |
| Unusual noises from unit | Loose parts, debris in fan, ice buildup | Check for loose panels, clean unit, allow defrost cycle to complete |
| Water leakage | Drain pipe clogged, improper installation, ice melting | Clear drain pipe, check installation angle, check for ice formation |
| Poor airflow | Dirty filters, blocked vents, fan speed low | Clean filters, clear obstructions, increase fan speed |
Error Codes
- E0: Protection device activated - Wait 3 minutes and restart
- E1: Indoor unit PCB error - Contact service center
- E3: High pressure error - Check for blocked vents or dirty filters
- E5: Communication error - Check wiring connections
- E6: Outdoor unit error - Contact service center
- E7: Indoor fan motor error - Check for obstructions
- EA: Room temperature sensor error - Contact service center
- U4: Indoor/outdoor communication error - Check wiring
Manual Downloads
Current Model Manuals
BRC1E63
Wireless Controller for FTXS Series
BRC1E52
Basic Wireless Controller
BRC1D52
Wired Controller
BRC1E73
Advanced Wireless Controller
Popular Previous Models
BRC1C52
Legacy Wireless Controller
BRC1B52
Basic Wired Controller
BRC1A52
Original Series Controller
BRC1D63
Wired Controller with Display