Daikin Air Conditioner Control Panel

User Manual & Operation Guide

FTXS Series / ATXS Series

Installation Guide

Tools Needed:

  • Phillips screwdriver
  • Wall anchors (if not included)
  • Level
  • Drill with appropriate bits
  • Measuring tape
  • Pencil for marking

Step-by-Step Installation

  1. Choose Installation Location: Select a location on an interior wall, approximately 1.5 meters above floor level, away from direct sunlight and heat sources.
  2. Prepare Mounting Area: Ensure the wall is clean, dry, and structurally sound. Avoid mounting on walls with excessive vibration.
  3. Mount Backplate: Use the provided template to mark screw positions. Drill holes and insert wall anchors if needed. Secure the backplate to the wall.
  4. Connect Wiring: Connect the control panel wires to the corresponding terminals on the indoor unit following the wiring diagram provided.
  5. Attach Control Panel: Align the control panel with the backplate and snap into place. Ensure all connections are secure.
  6. Power Connection: Ensure main power to the air conditioning system is turned off during installation. Restore power after installation is complete.
  7. Test Operation: Turn on the system and test all functions including temperature control, mode selection, and fan speed settings.
Warning: Installation should be performed by a qualified HVAC technician to ensure proper operation and maintain warranty coverage.

Specifications

Model Series BRC1E63 / BRC1E52
Type Wireless Remote Controller
Color White / Silver
Display Type LCD with Backlight
Control Range Up to 8 meters
Power Source 2 x AAA Batteries (included)
Battery Life Approximately 1 year (normal use)
Operating Temperature 0°C to 50°C
Dimensions (HxWxD) 85 x 60 x 20 mm
Weight 95 g (including batteries)
Compatible Models FTXS, ATXS, CTXS Series
Communication Infrared Wireless

Warranty Information

  • Full Warranty: 1 year parts and labor
  • Extended Coverage: 5 years on compressor when registered
  • Additional Coverage: Optional extended warranty available

For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com

Key Features

Intelligent Eye

Built-in motion sensor detects human presence and adjusts operation to save energy when the room is unoccupied, automatically resuming comfort settings when movement is detected.

Coanda Airflow

Advanced airflow control that spreads cool air along the ceiling for even temperature distribution without direct drafts, providing uniform comfort throughout the room.

Powerful Operation

Turbo mode provides rapid cooling or heating to reach desired temperature quickly, then automatically switches to normal operation for energy efficiency.

Quiet Operation

Night mode reduces operating noise to as low as 19 dB, ensuring undisturbed sleep while maintaining comfortable temperature settings.

3D Airflow

Adjustable vertical and horizontal louvers allow precise control of air direction, enabling customized comfort for any room layout.

Self-Clean Operation

Automatically dries the indoor unit after use to prevent mold and bacteria growth, maintaining air quality and reducing maintenance needs.

Operation Modes Explained

Cool Mode

Standard cooling operation with adjustable temperature settings from 16°C to 30°C

Heat Mode

Heating operation with temperature range from 16°C to 30°C for winter comfort

Dry Mode

Dehumidification function that removes excess moisture while maintaining room temperature

Fan Mode

Air circulation without cooling or heating, with multiple fan speed options

Auto Mode

Intelligent mode that automatically selects cooling or heating based on room temperature

Night Mode

Quiet operation with gradual temperature adjustment for sleeping comfort

Troubleshooting

Problem Possible Cause Solution
Control panel not responding Dead batteries, signal obstruction, out of range Replace batteries, ensure clear line of sight, move closer to indoor unit
Unit not cooling/heating Wrong mode selected, temperature setting incorrect, filter dirty Select correct mode, adjust temperature setting, clean air filter
Display blank or dim Batteries low, backlight timeout, display issue Replace batteries, press any button to activate, check battery contacts
Unusual noises from unit Loose parts, debris in fan, ice buildup Check for loose panels, clean unit, allow defrost cycle to complete
Water leakage Drain pipe clogged, improper installation, ice melting Clear drain pipe, check installation angle, check for ice formation
Poor airflow Dirty filters, blocked vents, fan speed low Clean filters, clear obstructions, increase fan speed

Error Codes

  • E0: Protection device activated - Wait 3 minutes and restart
  • E1: Indoor unit PCB error - Contact service center
  • E3: High pressure error - Check for blocked vents or dirty filters
  • E5: Communication error - Check wiring connections
  • E6: Outdoor unit error - Contact service center
  • E7: Indoor fan motor error - Check for obstructions
  • EA: Room temperature sensor error - Contact service center
  • U4: Indoor/outdoor communication error - Check wiring

Manual Downloads

Current Model Manuals

BRC1E63

Wireless Controller for FTXS Series

BRC1E52

Basic Wireless Controller

BRC1D52

Wired Controller

BRC1E73

Advanced Wireless Controller

Popular Previous Models

BRC1C52

Legacy Wireless Controller

BRC1B52

Basic Wired Controller

BRC1A52

Original Series Controller

BRC1D63

Wired Controller with Display

Note: For models not listed here, please visit the Daikin Support Website for complete documentation.