Installation Guide
Tools Needed:
- Phillips screwdriver
- Flathead screwdriver
- Wire stripper/cutter
- Level
- Drill with appropriate bits
- Voltage tester
Step-by-Step Installation
- Choose Installation Location: Select a location on an interior wall, away from direct sunlight, heat sources, and moisture.
- Mounting Bracket Installation: Secure the mounting bracket to the wall using appropriate anchors for your wall type.
- Electrical Connection: Turn off power at the circuit breaker. Connect control wires to the indoor unit following wiring diagram.
- Communication Cable: Connect communication cable between indoor and outdoor units, ensuring proper polarity.
- Mount Control Panel: Attach the control panel to the mounting bracket, ensuring it clicks securely into place.
- Power Restoration: Restore power at the circuit breaker and verify proper voltage supply.
- Initial Setup: Follow on-screen prompts to set language, time, date, and basic operating parameters.
- Test Operation: Test all functions including cooling, heating, fan speeds, and timer settings.
Specifications
| Model Series | FTXS-D / BRP1C6 |
| Type | Wall-mounted Air Conditioner Control Panel |
| Color | White / Silver |
| Display Type | LCD with Backlight |
| Control Interface | Touch Controls with Physical Buttons |
| Power Requirements | 24V AC, 50/60Hz |
| Communication Protocol | Daikin Proprietary Communication |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Dimensions (HxWxD) | 86 x 86 x 25 mm |
| Weight | 120 g |
| Wire Length | 1.5 meters (standard) |
| Compatible Models | FTXS09-25, FTXS35-60 Series |
Warranty Information
- Full Warranty: 1 year parts and labor
- Extended Warranty: Optional 3-year extended warranty available
- Compressor Warranty: 5 years on inverter compressor
For warranty service, contact Daikin Customer Service at 1-866-4-DAIKIN or visit Daikin.com
Key Features
Inverter Technology Control
Precise control of Daikin's inverter technology for optimal temperature maintenance, energy efficiency, and quiet operation.
Intelligent Eye Sensor
Energy-saving sensor detects human presence and adjusts operation accordingly, reducing energy consumption by up to 30%.
Coanda Airflow
Controls advanced airflow technology that spreads cool air along the ceiling for even room temperature distribution.
Powerful Operation
Special mode for rapid cooling/heating that operates at maximum capacity to reach desired temperature quickly.
Quiet Operation Mode
Special settings to minimize operational noise for nighttime or quiet environment operation.
Self-Cleaning Function
Controls the automatic cleaning cycle that dries the indoor unit to prevent mold and mildew growth.
Operating Modes Explained
Cooling Mode
Standard air conditioning operation with temperature range 16°C - 30°C (61°F - 86°F)
Heating Mode
Heat pump operation with temperature range 16°C - 30°C (61°F - 86°F)
Dry Mode
Dehumidification function that reduces humidity while maintaining comfortable temperature
Fan Mode
Air circulation only with 5-speed fan control (Auto, Low, Medium, High, Turbo)
Auto Mode
Automatic selection of cooling or heating based on room temperature
Night Mode
Quiet operation with gradual temperature adjustment for comfortable sleep
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Control panel not responding | Power issue, communication error | Check power supply, reset circuit breaker, check communication wiring |
| No cooling/heating | Wrong mode selection, temperature setting, filter clogged | Select correct mode, adjust temperature setting, clean air filter |
| Error code displayed | System malfunction, sensor failure | Note error code, consult error code list, contact technician |
| Unusual noises | Loose parts, fan obstruction, ice formation | Check for loose panels, clear obstructions, check for ice on coils |
| Water leakage | Clogged drain pipe, improper installation | Clear drain pipe, check installation slope |
| Poor airflow | Dirty filter, fan speed setting, blocked vents | Clean/replace filter, increase fan speed, clear obstructions |
Error Codes
- E0: Safety device activated - Contact service center
- E1: Indoor PCB error - Reset system, contact technician
- E3: High pressure error - Check for blockage, contact technician
- E5: Overload error - Reduce load, check power supply
- E6: Communication error - Check wiring connections
- E7: Outdoor fan motor error - Contact service center
- F3: Discharge pipe temperature error - Contact technician
- H3: High pressure switch error - Check refrigerant level
- H9: Outdoor temperature sensor error - Contact technician
- U0: Refrigerant shortage - Check for leaks, contact technician
Manual Downloads
Current Model Manuals
FTXS09-25CV1B
9,000-25,000 BTU Control Panel
FTXS35-60CV1B
35,000-60,000 BTU Control Panel
BRP1C61
Wi-Fi Enabled Control Panel
BRP1C62
Advanced Touch Control Panel
Popular Previous Models
FTXS09-20CV1B
9,000-20,000 BTU Control
FTXS25-50CV1B
25,000-50,000 BTU Control
BRP1A42
Basic Control Panel
BRP1B61
Standard Control Panel