Installation Guide
Tools Needed:
- Drill with hole saw attachment
- Level
- Screwdrivers (flat and Phillips)
- Torque wrench
- Vacuum pump
- Manifold gauge set
- Flaring tool
Step-by-Step Installation
- Choose Installation Location: Select a location with proper clearance (at least 15cm from ceiling, 30cm from walls) and away from heat sources.
- Mount Indoor Unit Bracket: Secure the mounting bracket to the wall using appropriate anchors and ensure it is perfectly level.
- Drill Wall Hole: Drill a 70mm hole through the wall at a slight downward angle to the outside for proper drainage.
- Connect Refrigerant Pipes: Connect copper pipes between indoor and outdoor units, ensuring proper flaring and torque specifications.
- Electrical Connection: Connect to a dedicated circuit with proper grounding according to local electrical codes.
- Vacuum and Charge: Evacuate the system using a vacuum pump for at least 15 minutes, then release the pre-charged refrigerant.
- Test Run: Test all functions including cooling, heating, fan speeds, and remote control operation.
Specifications
| Model Series | FTXS Series |
| Type | Split System Air Conditioner |
| Color | White / Silver |
| Cooling Capacity | 9,000 BTU/h |
| Heating Capacity | 10,000 BTU/h |
| Noise Level (Indoor) | 19 dB (Quiet Mode) |
| Control Type | Remote Control with LCD Display |
| Energy Rating | A+++ (Most Efficient) |
| Power Requirements | 220-240V, 50Hz, 1 Phase |
| Refrigerant | R32 (Eco-friendly) |
| Dimensions Indoor (HxWxD) | 29.5 x 79.8 x 24.5 cm |
| Dimensions Outdoor (HxWxD) | 55 x 79.8 x 28.9 cm |
| Weight Indoor/Outdoor | 9 kg / 28 kg |
Warranty Information
- Full Warranty: 5 years on compressor
- Parts Warranty: 5 years on all parts
- Labor Warranty: 1 year on installation labor
- Extended Coverage: Optional extended warranty available
For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com
Key Features
Inverter Technology
Daikin's advanced inverter technology adjusts compressor speed to maintain desired temperature, reducing energy consumption by up to 30% compared to conventional units.
Coanda Airflow
Innovative Coanda airflow design ensures even temperature distribution throughout the room by directing cool air along the ceiling for optimal comfort.
Quiet Operation
Specialized noise reduction technology delivers ultra-quiet operation as low as 19 dB, quieter than a whisper for undisturbed comfort.
Flash Streamer Technology
Advanced air purification system breaks down allergens, odors, and bacteria, providing cleaner, healthier indoor air quality.
Intelligent Eye
Energy-saving sensor detects human movement and adjusts operation accordingly, saving energy when the room is unoccupied.
Powerful Operation
Quick cooling and heating capabilities reach desired temperatures faster with powerful operation mode for immediate comfort.
Operation Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature and fan speed settings
Heat Mode
Efficient heating operation with defrost cycle for winter comfort
Dry Mode
Dehumidification function that removes excess moisture without overcooling
Fan Mode
Air circulation only with multiple fan speed options
Auto Mode
Intelligent mode that automatically selects cooling or heating based on room temperature
Night Mode
Quiet operation with gradual temperature adjustment for comfortable sleep
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | Power issue, remote control batteries, circuit breaker | Check power supply, replace remote batteries, reset circuit breaker |
| Poor cooling/heating | Dirty filters, blocked airflow, incorrect temperature setting | Clean filters, clear obstructions, set appropriate temperature |
| Water leaking indoors | Clogged drain pipe, improper installation angle | Clear drain pipe, ensure proper installation slope |
| Unusual noises | Loose parts, debris in fan, ice buildup | Tighten components, clean unit, check for ice formation |
| Remote not working | Dead batteries, signal obstruction, sensor issue | Replace batteries, ensure line of sight, check sensor |
| Frozen evaporator | Dirty filters, low refrigerant, fan motor issue | Clean filters, check refrigerant charge, inspect fan motor |
Error Codes
- E0: Protection device activated - Wait 3 minutes and restart
- E1: Indoor PCB issue - Contact service center
- E3: High pressure protection - Check for blockage in outdoor unit
- E5: Overload protection - Reduce load or check power supply
- E6: Communication error - Check wiring between indoor and outdoor units
- E7: Outdoor fan motor error - Contact service center
- F3: Evaporator temperature sensor error - Contact service center
Manual Downloads
Current Model Manuals
FTXS09LV1W
9,000 BTU Wall Mounted
FTXS12LV1W
12,000 BTU Wall Mounted
FTXS18LV1W
18,000 BTU Wall Mounted
FTXS24LV1W
24,000 BTU Wall Mounted
Popular Previous Models
FTXS35LV1B
9,000 BTU Basic Model
FTXS50LV1S
12,000 BTU Silver Model
FTXS60LV1W
18,000 BTU White Model
FTXS71LV1W