Installation Guide
Tools Needed:
- Vacuum pump with gauge manifold
- Refrigerant charging scale
- Torque wrench set
- Flaring tool set
- Multimeter
- Level
- Drill with hole saw
Step-by-Step Installation
- Select Installation Location: Choose a location with proper clearance (minimum 30cm from walls and ceilings) on a solid wall that can support the unit's weight.
- Install Wall Bracket: Securely mount the outdoor unit bracket using appropriate anchors for your wall type, ensuring it is perfectly level.
- Create Wall Opening: Drill a 65mm hole through the wall for refrigerant piping, drainage, and electrical connections, ensuring proper slope for drainage.
- Connect Refrigerant Pipes: Connect indoor and outdoor units with copper pipes using flare connections, ensuring proper insulation on both pipes.
- Electrical Connection: Connect power supply to the outdoor unit following local electrical codes. Use dedicated circuit with proper grounding.
- Vacuum and Charge: Evacuate the system using a vacuum pump for at least 15 minutes, then charge with specified amount of R32 refrigerant.
- Test Operation: Test all functions including cooling, heating, fan speeds, and remote control operation. Check for leaks and proper drainage.
Specifications
| Model Series | FTXM-R |
| Type | Split System Air Conditioner |
| Color | White / Titanium |
| Cooling Capacity | 9,000 BTU/h (2.6 kW) |
| Heating Capacity | 10,000 BTU/h (2.9 kW) |
| Noise Level (Indoor/Outdoor) | 19 dB / 46 dB |
| Control Type | Wireless Remote with LCD Display |
| Energy Rating | A+++ (Most Efficient) |
| Refrigerant Type | R32 (Eco-friendly) |
| Power Requirements | 220-240V, 50Hz, 1Ph |
| Dimensions Indoor (HxWxD) | 29.5 x 79.8 x 20.0 cm |
| Dimensions Outdoor (HxWxD) | 55.0 x 79.5 x 28.5 cm |
| Weight (Indoor/Outdoor) | 8.5 kg / 26.0 kg |
Warranty Information
- Full Warranty: 3 years parts and labor
- Compressor Warranty: 5 years on inverter compressor
- Extended Coverage: Optional 7-year extended warranty available
For warranty service, contact Daikin Customer Service at 1-800-432-1342 or visit Daikin.com
Key Features
Inverter Technology
Daikin's advanced inverter compressor adjusts power output to match exact cooling/heating needs, providing consistent comfort while reducing energy consumption by up to 30%.
Coanda Airflow
Intelligent airflow control spreads cool air along the ceiling for even temperature distribution without direct drafts, ensuring comfortable cooling throughout the room.
Flash Streamer Technology
Advanced air purification system breaks down allergens, odors, and bacteria, providing cleaner, healthier indoor air quality for allergy sufferers.
Quiet Operation
Specialized noise reduction technology ensures whisper-quiet operation as low as 19dB, quieter than a library, for undisturbed sleep and work environments.
Smart Control
Wi-Fi enabled for remote control via smartphone app, allowing scheduling, temperature adjustments, and energy monitoring from anywhere.
Powerful Heating
Advanced heat pump technology provides efficient heating even in extreme cold conditions down to -15°C, ensuring year-round comfort.
Operation Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature and fan speed settings for optimal comfort
Heat Mode
Efficient heating operation using inverter heat pump technology for winter comfort
Dry Mode
Dehumidification function that removes excess moisture without overcooling the room
Fan Mode
Circulation only mode with multiple fan speeds for air movement without cooling/heating
Auto Mode
Intelligent mode that automatically selects cooling or heating based on room temperature
Night Mode
Quiet operation with gradual temperature adjustment for undisturbed sleep
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | Power outage, circuit breaker tripped, remote battery dead | Check power supply, reset circuit breaker, replace remote batteries |
| Poor cooling/heating | Dirty filters, blocked airflow, incorrect temperature setting | Clean air filters, clear obstructions, set appropriate temperature |
| Water leaking indoors | Clogged drain pipe, improper installation slope | Clear drain pipe, ensure proper drainage slope |
| Unusual noises | Loose parts, debris in fan, ice buildup | Tighten mounting, clear debris, check for proper operation |
| Remote not working | Dead batteries, signal obstruction, sensor issue | Replace batteries, ensure line of sight, check sensor |
| Frequent cycling | Dirty filters, thermostat location, oversized unit | Clean filters, relocate thermostat, consult technician |
Error Codes
- E0: Protection device activated - Wait 3 minutes and restart
- E1: Indoor PCB issue - Contact service center
- E3: High pressure error - Check for blockage, clean outdoor unit
- E5: Communication error - Check wiring between units
- E6: Outdoor unit fan motor error - Contact service center
- E7: Outdoor unit temperature sensor error - Contact service center
- EA: Refrigerant leak detected - Contact certified technician
Manual Downloads
Current Model Manuals
FTXM35R
3.5kW Inverter Split System
FTXM50R
5.0kW Inverter Split System
FTXM60R
6.0kW Inverter Split System
FTXM71R
7.1kW Inverter Split System
Popular Previous Models
FTXS35G
3.5kW Wall Mounted Unit
FTXS50G
5.0kW Wall Mounted Unit
FTXN50K
5.0kW Premium Inverter
FTXJ25M
2.5kW Basic Split System