DeLonghi Air Conditioner

User Manual & Installation Guide

Portable & Split System Models

Installation Guide

Tools Needed:

  • Drill with hole saw attachment
  • Screwdriver set
  • Level
  • Tape measure
  • Adjustable wrench
  • Vacuum for cleanup

Step-by-Step Installation

  1. Choose Installation Location: Select a location near a window or exterior wall with proper electrical access and adequate clearance for airflow.
  2. Prepare Window Kit: For portable models, adjust the window sealing kit to fit your window dimensions securely.
  3. Install Exhaust Hose: Connect the exhaust hose to the unit and secure it to the window kit, ensuring a tight seal to prevent hot air backflow.
  4. Position the Unit: Place the air conditioner on a flat, stable surface with at least 50cm clearance on all sides for optimal airflow.
  5. Electrical Connection: Plug into a dedicated 220-240V, 50Hz grounded outlet. Do not use extension cords or power strips.
  6. Drainage Setup: For continuous operation, connect the drain hose to the unit and route it to a suitable drainage point.
  7. Test Operation: Run the air conditioner in cooling mode for 15 minutes to verify proper operation and check for any leaks or unusual noises.
Warning: Installation of split system models must be performed by certified HVAC technicians to ensure proper refrigerant handling and electrical safety.

Specifications

Model Series Pinguino PAC EX系列
Type Portable Air Conditioner
Color White / Silver
Cooling Capacity 10,000 - 14,000 BTU/h
Heating Capacity 10,500 BTU/h (Heat pump models)
Noise Level 52 - 65 dB
Control Type Digital Display with Remote Control
Energy Rating A++ (Energy Efficient)
Power Consumption 1,100 - 1,500 W
Power Requirements 220-240V, 50Hz, 10-16A
Dimensions (HxWxD) 70 x 45 x 35 cm
Weight 25 - 35 kg
Refrigerant R290 / R32 (Eco-friendly)

Warranty Information

  • Full Warranty: 2 years parts and labor
  • Compressor Warranty: 5 years on inverter compressor
  • Extended Coverage: Optional 3-year extension available

For warranty service, contact DeLonghi Customer Service at 1-800-322-3848 or visit DeLonghi.com

Key Features

Inverter Technology

Advanced inverter compressor adjusts cooling/heating power continuously, maintaining consistent temperature while reducing energy consumption by up to 40%.

3-in-1 Functionality

Combines air conditioning, dehumidification, and fan functions in one unit, providing year-round climate control for your living space.

Auto Swing Louvers

Automatically oscillating vertical and horizontal louvers distribute air evenly throughout the room, eliminating hot or cold spots.

24-Hour Timer

Programmable timer allows you to set the unit to turn on/off at specific times, ensuring comfort when you need it while saving energy.

Sleep Mode

Quiet operation with gradual temperature adjustment throughout the night for optimal sleeping conditions and energy efficiency.

Self-Evaporation System

Innovative system reuses condensation to cool the unit, reducing the need for manual drainage during normal operation.

Operating Modes Explained

Cool Mode

Standard air conditioning function that cools and dehumidifies the room to your set temperature

Heat Mode

Reverse cycle heating (heat pump models only) for efficient room heating during colder months

Dry Mode

Dehumidification function that removes excess moisture without significant cooling

Fan Mode

Circulates air without cooling or heating, with multiple speed settings

Auto Mode

Intelligent mode that automatically selects cooling or heating based on room temperature

Turbo Mode

Maximum power setting for rapid cooling or heating when needed

Troubleshooting

Problem Possible Cause Solution
Unit not turning on Power issue, full water tank, timer setting Check power connection, empty water tank, check timer settings
Poor cooling performance Dirty filters, blocked exhaust, high ambient temperature Clean air filters, check exhaust hose, ensure room temperature is within operating range
Water leakage Full water tank, improper drainage setup, clogged drain Empty water tank, check drain hose connection, clean drain system
Unusual noises Loose parts, foreign objects, unbalanced unit Check for loose components, remove obstructions, ensure unit is level
Remote control not working Dead batteries, signal obstruction, distance too far Replace batteries, ensure clear line of sight, move closer to unit
Error codes displayed System malfunction, sensor failure, protection mode Refer to error code guide below, reset unit, contact service if persistent

Error Codes

  • E1/E2: Room temperature sensor error - Check sensor connection
  • E3/E4: Evaporator temperature sensor error - Contact service center
  • E5: Communication error - Reset unit, check control board
  • E6: Water tank full - Empty water collection tank
  • E7: Fan motor error - Check fan operation, contact service
  • E8: Compressor protection - Wait 3 minutes, restart unit
  • P1/P2: High/low pressure protection - Check ventilation, contact service

Manual Downloads

Current Model Manuals

PAC EX100

10,000 BTU Portable AC

PAC EX120

12,000 BTU Portable AC

PAC EX140

14,000 BTU Portable AC

PAC EX100H

10,000 BTU Heat/Cool

Popular Previous Models

PAC N81

8,000 BTU Portable AC

PAC T126

12,600 BTU Portable AC

PAC C85

8,500 BTU Silent Series

PAC AN90

9,000 BTU Advanced

Split System Models

DAS09

9,000 BTU Split AC

DAS12

12,000 BTU Split AC

DAS18

18,000 BTU Split AC

DAS24

24,000 BTU Split AC

Note: For models not listed here, please visit the DeLonghi Support Website for complete documentation.