Installation Guide
Tools Needed:
- Drill with hole saw attachment
- Screwdrivers (flat and Phillips)
- Level
- Tape measure
- Adjustable wrench
- Vacuum pump and gauge manifold
Step-by-Step Installation
- Choose Installation Location: Select a location with proper wall support, away from direct sunlight and heat sources, with adequate clearance for airflow.
- Mount Indoor Unit Bracket: Securely mount the bracket to the wall using appropriate anchors for your wall type.
- Install Outdoor Unit: Place outdoor unit on stable surface with proper vibration pads, ensuring minimum 30cm clearance on all sides.
- Connect Refrigerant Lines: Connect copper pipes between indoor and outdoor units, ensuring proper insulation on all connections.
- Electrical Connection: Connect to dedicated circuit with proper grounding according to local electrical codes.
- Drainage Setup: Install drain hose with continuous downward slope to ensure proper condensate drainage.
- Vacuum and Charge: Evacuate system with vacuum pump and charge with specified refrigerant amount.
- Test Run: Run system through complete cooling and heating cycles to check operation and temperature performance.
Specifications
| Model Series | Pinguino PAC EX130 Silent |
| Type | Portable Air Conditioner |
| Color | White / Silver |
| Cooling Capacity | 13,000 BTU/h |
| Heating Capacity | 12,500 BTU/h |
| Room Coverage | Up to 45 m² (485 sq ft) |
| Noise Level | 49 dB (Low) / 65 dB (High) |
| Control Type | Digital Display with Remote Control |
| Energy Rating | A++ (Cooling) / A+ (Heating) |
| Power Requirements | 230V, 50Hz, 10A |
| Dimensions (HxWxD) | 75 x 45 x 35 cm |
| Weight | 32 kg |
| Refrigerant | R32 (Eco-friendly) |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 5 years on rotary compressor
- Extended Coverage: Optional 3-year extension available
For warranty service, contact DeLonghi Customer Service at 1-800-322-3848 or visit DeLonghi.com
Key Features
Silent Technology
Advanced noise reduction technology with specially designed fan blades and insulated compressor compartment for ultra-quiet operation.
3-in-1 Functionality
Combines cooling, dehumidifying, and fan functions in one unit with automatic mode selection based on room conditions.
Auto Swing Louvers
Automatically oscillating vertical and horizontal louvers ensure even air distribution throughout the room without cold spots.
24-Hour Timer
Programmable timer allows you to set the unit to turn on/off at specific times for energy savings and comfort.
Self-Diagnosis System
Intelligent system detects and displays error codes for easy troubleshooting and maintenance alerts.
Auto Restart
Automatically resumes previous settings after power interruption, maintaining your preferred comfort level.
Operating Modes Explained
Cool Mode
Standard cooling operation with adjustable temperature settings from 16°C to 30°C
Dry Mode
Dehumidification function that removes excess moisture without overcooling the room
Fan Mode
Circulates air without cooling, with multiple speed settings for customized airflow
Auto Mode
Intelligent mode that automatically selects cooling, drying, or fan based on room temperature
Sleep Mode
Gradually adjusts temperature and reduces fan speed for quiet, energy-efficient nighttime operation
Turbo Mode
Maximum power setting for rapid cooling when quick temperature reduction is needed
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit not turning on | Power issue, timer setting, remote control batteries | Check power supply, verify timer settings, replace remote batteries |
| Poor cooling performance | Dirty filters, blocked vents, room too large | Clean filters, ensure proper ventilation, check room size compatibility |
| Water leakage | Drain hose blocked, unit not level, full condensate tank | Clear drain hose, level the unit, empty condensate tank |
| Unusual noises | Loose parts, debris in fan, vibration | Tighten all screws, clean fan area, check unit stability |
| Remote not working | Dead batteries, signal obstruction, distance | Replace batteries, ensure line of sight, move closer to unit |
| Unit freezing up | Low temperature setting, dirty filters, low refrigerant | Increase temperature setting, clean filters, contact technician |
Error Codes
- E1: Room temperature sensor failure - Contact service
- E2: Evaporator temperature sensor failure - Contact service
- E3: Condenser temperature sensor failure - Contact service
- E4: Communication error - Check connections
- E5: Overcurrent protection - Wait 3 minutes and restart
- P1: High pressure protection - Clean filters and check ventilation
- P2: Low pressure protection - Contact technician
- FL: Full condensate tank - Empty water tank
Manual Downloads
Current Model Manuals
PAC EX130 Silent
13,000 BTU Portable AC
PAC AN110
11,000 BTU Portable AC
PAC N82 ECO
8,200 BTU Eco Portable AC
Split S12HP
12,000 BTU Split System
Popular Previous Models
PAC T126
12,600 BTU Portable AC
PAC C100
10,000 BTU Portable AC
Split S09HP
9,000 BTU Split System
PAC N77
7,700 BTU Portable AC