Installation Guide
Tools Needed:
- Drill with hole saw attachment
- Screwdrivers (flat and Phillips)
- Wire strippers/crimpers
- Roof sealant (RV approved)
- Measuring tape
- Level
Step-by-Step Installation
- Choose Installation Location: Select a location on the RV roof with adequate structural support and clear of obstructions.
- Prepare Roof Opening: Mark and cut the roof opening according to the unit's dimensions, ensuring proper sealing area.
- Install Roof Curb: Secure the roof curb using appropriate fasteners and seal with RV roof sealant around all edges.
- Electrical Connection: Connect to the RV's 120V AC power supply following local electrical codes and manufacturer specifications.
- Mount Air Conditioner: Lift the unit onto the roof curb and secure with provided fasteners.
- Connect Ductwork: Connect the duct system to the unit's air distribution box if applicable.
- Test Operation: Test all functions including cooling, fan speeds, and thermostat operation.
Specifications
| Model Series | PENGUIN II |
| Type | Roof Mount RV Air Conditioner |
| Color | White / Low Profile |
| Cooling Capacity | 13,500 BTU |
| Noise Level | 58 dB (Low Speed) |
| Control Type | Digital Thermostat with Remote |
| Energy Rating | Energy Efficient |
| Air Flow | 320 CFM |
| Power Requirements | 115V, 60Hz, 12.5A |
| Dimensions (LxWxH) | 28.5 x 27.5 x 11.5 inches |
| Weight | 78 lbs |
| Refrigerant | R-410A |
Warranty Information
- Full Warranty: 2 years parts and labor
- Compressor Warranty: 5 years on sealed system
- Additional Coverage: Optional extended warranty available
For warranty service, contact Dometic Customer Service at 1-800-544-4881 or visit Dometic.com
Key Features
Low Profile Design
Streamlined design reduces wind resistance and improves fuel efficiency while maintaining optimal cooling performance.
Quiet Operation
Advanced compressor technology and insulated housing provide quiet operation for comfortable RV living.
Digital Control System
Precise temperature control with multiple fan speeds and programmable settings for optimal comfort and energy efficiency.
Heat Pump Option
Available with reverse cycle heat pump for year-round climate control in your RV.
Easy Maintenance
Removable filter and accessible components make routine maintenance simple and straightforward.
Durable Construction
UV-resistant housing and corrosion-resistant components ensure long-lasting performance in all weather conditions.
Operating Modes
Cooling Mode
Standard air conditioning operation with adjustable temperature settings
Fan Only Mode
Circulates air without cooling for ventilation and air circulation
Heat Mode
Reverse cycle heating on heat pump models (if equipped)
Auto Mode
Automatically switches between cooling and fan to maintain set temperature
Dehumidify Mode
Reduces humidity while maintaining comfortable temperature
Eco Mode
Energy-saving operation with optimized performance
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit won't start | Power issue, thermostat setting, circuit breaker | Check power supply, verify thermostat settings, reset circuit breaker |
| Poor cooling performance | Dirty filter, low refrigerant, blocked airflow | Clean or replace filter, check for obstructions, contact service if refrigerant low |
| Water leaking inside RV | Clogged drain, improper installation, condensation | Clear drain tube, check installation angle, ensure proper sealing |
| Unusual noises | Loose components, debris in fan, motor issues | Tighten mounting hardware, clear debris from fan, contact service for motor issues |
| Fan runs but no cooling | Compressor issue, thermostat problem, electrical fault | Check compressor operation, verify thermostat function, check electrical connections |
| Unit cycles on/off frequently | Dirty coils, low refrigerant, thermostat location | Clean condenser coils, check refrigerant charge, relocate thermostat if in direct sunlight |
Error Codes
- E1: Room temperature sensor fault - Check sensor connection
- E2: Evaporator temperature sensor fault - Check sensor connection
- E3: Condenser temperature sensor fault - Check sensor connection
- E4: Communication error - Check control board connections
- E5: Compressor overload - Allow unit to cool, check voltage
- E6: Fan motor fault - Check fan motor and connections
Manual Downloads
Current Model Manuals
PENGUIN II
13,500 BTU Low Profile
Brisk II
15,000 BTU High Efficiency
Polar White
11,000 BTU Compact
Penguin II HP
13,500 BTU with Heat Pump
Popular Previous Models
Brisk Air
13,500 BTU Standard
Penguin I
11,000 BTU Original
Duo-Therm
15,000 BTU Classic
Polar Cub
7,000 BTU Compact