Installation Guide
Tools Needed:
- Adjustable wrench set
- Level
- Screwdrivers (flat and Phillips)
- Pipe wrench
- Tape measure
- Air pressure gauge
Step-by-Step Installation
- Choose Installation Location: Select a clean, dry, well-ventilated location with adequate space for maintenance access and proper airflow.
- Foundation Preparation: Place on a solid, level concrete floor capable of supporting the compressor's weight and vibration.
- Electrical Connection: Connect to proper power supply according to model specifications. All wiring must comply with local electrical codes.
- Air System Connection: Install proper air lines with minimum pressure drop. Include shut-off valve, drain leg, and pressure regulator.
- Check Oil Level: Verify proper oil level in sight glass before initial startup.
- Pressure Settings: Adjust pressure switch cut-in and cut-out settings according to application requirements.
- Test Run: Run compressor through complete cycle to check for leaks, proper operation, and correct pressure buildup.
Specifications
| Model Series | Type 30 |
| Type | Reciprocating Piston Air Compressor |
| Configuration | Two-Stage, Air-Cooled |
| Horsepower | 5 HP - 25 HP |
| Maximum Pressure | 175 PSI |
| Air Delivery (CFM) | 18.1 - 77.2 CFM at 175 PSI |
| Tank Capacity | 60 - 240 Gallons |
| Noise Level | 75 - 85 dB(A) |
| Power Requirements | 230V/460V, 3 Phase, 60Hz |
| Dimensions (Varies by Model) | Approx. 48" x 30" x 65" |
| Weight | 450 - 1200 lbs |
| Oil Capacity | 1.5 - 3.5 Quarts |
Warranty Information
- Full Warranty: 2 years parts and labor
- Pump Warranty: 5 years on compressor pump
- Tank Warranty: Lifetime limited warranty on ASME tank
- Additional Coverage: Optional extended warranty available
For warranty service, contact Ingersoll Rand Customer Service at 1-800-247-3865 or visit ingersollrand.com
Key Features
Two-Stage Compression
Delivers higher efficiency and cooler operation by compressing air in two stages with intercooling between stages for improved performance and durability.
Iron Cylinder Sleeves
Durable cast iron cylinder sleeves provide superior heat dissipation and extended service life compared to aluminum designs.
Pressure Lubrication System
Full pressure lubrication ensures proper oil distribution to all moving parts, reducing wear and extending component life.
ASME Certified Tanks
All tanks meet ASME safety standards and include lifetime limited warranty for maximum safety and reliability.
Thermal Overload Protection
Built-in thermal overload protection prevents motor damage from overheating during extended operation or high ambient temperatures.
Low Oil Protection
Automatic shutdown when oil level drops below safe operating minimum prevents catastrophic pump failure.
Type 30 Technology Explained
Dual Pressure Control
Separate pressure switches for loaded and unloaded operation optimize efficiency and reduce cycling
Intercooling System
Between-stage cooling reduces air temperature and moisture content for better efficiency
Heavy-Duty Valves
Stainless steel valves with precision machining for reliable operation and easy maintenance
Vibration Isolation
Rubber isolation mounts reduce noise transmission and prevent vibration damage to foundation
Automatic Tank Drain
Optional automatic tank drain removes condensate without manual intervention
Easy Access Panels
Removable side panels provide quick access to components for routine maintenance
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor won't start | Power issue, pressure switch fault, thermal overload tripped | Check power supply, reset overload, verify pressure switch operation |
| Low air pressure output | Air leaks, worn valves, intake filter clogged | Check for leaks, inspect valves, clean or replace air filter |
| Excessive noise/vibration | Loose mounting, worn bearings, piston slap | Tighten mounting bolts, check bearings, inspect piston clearance |
| Overheating | Dirty cooling fins, high ambient temperature, restricted airflow | Clean cooling surfaces, improve ventilation, check fan operation |
| Excessive oil consumption | Worn rings, leaking gaskets, overfilling | Check compression, inspect for leaks, verify proper oil level |
| Frequent cycling | Air leaks, faulty check valve, undersized tank | Locate and repair leaks, replace check valve, verify system demand |
Common Error Indicators
- Red Oil Light: Low oil pressure - Check oil level and pump
- Thermal Overload Trip: Motor overheating - Allow cool down, check ventilation
- High Temperature Shutdown: System overheating - Clean cooling surfaces, check thermostat
- Pressure Switch Failure: No pressure control - Replace pressure switch assembly
- Unloader Valve Stuck: Hard starting - Clean or replace unloader valve
- Check Valve Leak: Tank pressure drops - Replace check valve
Manual Downloads
Type 30 Series Manuals
T30 5HP 60G
5 HP, 60 Gallon Tank
T30 7.5HP 80G
7.5 HP, 80 Gallon Tank
T30 10HP 120G
10 HP, 120 Gallon Tank
T30 15HP 120G
15 HP, 120 Gallon Tank