Installation Guide
Tools Needed:
- Refrigeration gauge manifold
- Vacuum pump
- Torque wrench
- Flaring tool
- Pipe cutter
- Multimeter
- Level
Step-by-Step Installation
- Select Installation Location: Choose a location for outdoor unit with proper clearance (minimum 30cm from walls) on a solid, level concrete pad.
- Mount Indoor Units: Install indoor units on interior walls with proper spacing from ceiling (minimum 15cm) and walls (minimum 10cm).
- Install Refrigerant Piping: Connect copper piping between outdoor and indoor units using proper insulation and flare connections.
- Electrical Connections: Connect power supply to outdoor unit (240V, 60Hz) and indoor units according to local electrical codes.
- Communication Wiring: Install communication wiring between outdoor unit and all indoor units using shielded cable.
- Drainage System: Install condensate drain lines with proper slope (minimum 1/100 gradient) and trap for each indoor unit.
- Vacuum and Charge: Evacuate system to 500 microns, hold vacuum for 30 minutes, then charge with specified refrigerant amount.
- System Test: Power on system, test all functions, modes, and verify proper operation of all zones.
Specifications
| Model Series | MXZ-8C60NA |
| System Type | Multi-Zone Inverter Heat Pump |
| Cooling Capacity | 60,000 BTU/h |
| Heating Capacity | 68,000 BTU/h |
| Max Connected Indoor Units | 8 Zones |
| Refrigerant Type | R-410A |
| Energy Efficiency Ratio (EER) | 12.5 |
| Heating Seasonal Performance (HSPF) | 10.5 |
| Power Requirements | 208-230V, 60Hz, 30A |
| Operating Temperature Range | -13°F to 115°F (-25°C to 46°C) |
| Outdoor Unit Dimensions (HxWxD) | 43 x 35 x 15 inches |
| Outdoor Unit Weight | 187 lbs |
| Sound Level (Outdoor Unit) | 58 dB(A) |
Warranty Information
- Compressor Warranty: 7 years parts
- Parts Warranty: 5 years parts
- Labor Warranty: 1 year labor
- Extended Coverage: Optional Diamond Contractor warranty available
For warranty service, contact Mitsubishi Electric at 1-800-433-4822 or visit MitsubishiComfort.com
Key Features
Inverter-Driven Compressor
Advanced DC inverter technology provides precise temperature control, rapid cooling/heating, and superior energy efficiency by adjusting compressor speed to match demand.
Multi-Zone Flexibility
Connect up to 8 indoor units to one outdoor unit, allowing independent temperature control in different zones for customized comfort and energy savings.
Hyper-Heating INVERTER®
Provides 100% heating capacity at 5°F (-15°C) and continues to operate efficiently in temperatures as low as -13°F (-25°C).
kumo cloud® Integration
Wi-Fi enabled for remote control via smartphone app, allowing scheduling, energy monitoring, and control from anywhere with internet access.
Advanced Filtration System
Multi-stage filtration including plasma and enzyme filters removes allergens, odors, and microscopic particles for improved indoor air quality.
Quiet Operation
Sound levels as low as 19 dB for indoor units and 58 dB for outdoor units provide whisper-quiet comfort without disruption.
Indoor Unit Options
Wall-Mounted
Sleek, compact design with wide airflow for residential applications
Ceiling Cassette
4-way airflow, flush-mount design for commercial spaces
Ducted Concealed
Hidden installation with flexible ducting options
Floor Standing
Vertical design for spaces with limited wall space
Ceiling Suspended
Industrial design for large open spaces
Horizontal Ducted
Low-profile design for shallow ceiling cavities
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| System won't start | Power outage, circuit breaker tripped, remote control batteries dead | Check power supply, reset breaker, replace remote batteries |
| Poor cooling/heating | Dirty filters, blocked airflow, refrigerant leak | Clean filters, clear obstructions, contact technician for leak check |
| Water leakage | Clogged drain line, improper slope, frozen coil | Clear drain line, ensure proper slope, check for ice on coil |
| Unusual noises | Loose parts, debris in fan, vibration | Tighten mounting hardware, clear debris, check isolation |
| Error code displayed | System fault, sensor failure, communication error | Note error code, power cycle system, contact technician |
| Uneven temperatures | Improper zoning, airflow restrictions, sizing issue | Check zone dampers, clear vents, verify system capacity |
Common Error Codes
- E0: Outdoor unit protection - Check outdoor unit operation
- E1: Indoor unit PCB error - Power cycle indoor unit
- E6: Communication error - Check wiring between units
- E7: Outdoor fan motor error - Check fan operation
- H0: Refrigerant leak detected - Contact technician immediately
- H3: High pressure protection - Check for restrictions
- H9: Outdoor temperature sensor error - Check sensor connection
- P1: Voltage protection - Check power supply voltage
Manual Downloads
Current Model Manuals
MXZ-8C60NA
8-Zone Hyper-Heat System
MXZ-5C42NA
5-Zone Standard System
MXZ-3C24NA
3-Zone Compact System
MXZ-4C36NA
4-Zone Smart System
Popular Previous Models
MXZ-4B36NA
4-Zone Basic System
MXZ-8B60NA
8-Zone Commercial System
PUMY-P60NKMU
Ducted System
MSZ-GL06NA