Installation Guide
Tools Needed:
- Adjustable wrenches
- Pipe thread sealant
- Voltage tester
- Level
- Pipe cutter
- Safety glasses and gloves
Step-by-Step Installation
- Select Location: Choose a clean, dry, well-ventilated area with adequate clearance for maintenance and airflow.
- Foundation Preparation: Ensure a solid, level concrete foundation to minimize vibration and noise transmission.
- Electrical Connection: Connect to proper power supply per local electrical codes. Quincy compressors typically require dedicated circuits.
- Air System Piping: Install proper size piping with drip legs and shutoff valves. Use threaded connections with appropriate sealant.
- Intake Air: Ensure clean, cool intake air free from contaminants. Install intake filter in clean location.
- Drain Installation: Connect condensate drain to proper disposal system following local regulations.
- Pressure Settings: Set cut-in and cut-out pressures according to application requirements and manufacturer specifications.
- Initial Startup: Perform initial startup without load, check rotation direction, then gradually apply load while monitoring operation.
Specifications
| Model Series | QT & QGS Series |
| Type | Rotary Screw & Reciprocating Compressors |
| Horsepower Range | 5 HP to 350 HP |
| Pressure Range | 80 PSI to 200 PSI |
| CFM Capacity | 18 CFM to 1500 CFM |
| Control Type | Electronic Controls with Digital Display |
| Noise Level | 70 dB to 85 dB |
| Tank Capacity | 60 Gallon to 240 Gallon |
| Power Requirements | 208-230V/460V, 3 Phase, 60Hz |
| Dimensions (LxWxH) | Varies by model (60"x30"x50" to 120"x60"x80") |
| Weight | 500 lbs to 3000 lbs |
| Oil Capacity | 2 Gallons to 15 Gallons |
Warranty Information
- Standard Warranty: 2 years parts and labor
- Air End Warranty: 5 years on rotary screw air ends
- Extended Coverage: Optional extended warranty packages available
- Warranty Registration: Required within 60 days of installation
For warranty service, contact Quincy Compressor Customer Service at 1-800-874-0555 or visit QuincyCompressor.com
Key Features
Quincy QE Series Air End
Patented asymmetric screw profile provides superior efficiency with lower energy consumption and extended service life compared to conventional designs.
Intellisys Controller
Advanced microprocessor control system monitors and adjusts compressor operation for optimal performance, energy savings, and system protection.
Pressure Flow Control
Automatically adjusts compressor output to match air demand, reducing energy consumption during partial load conditions by up to 35%.
QRP GoldĀ® Lubricant
Proprietary synthetic lubricant provides extended service intervals, superior heat transfer, and excellent water separation characteristics.
Vertical Tank Design
Space-saving vertical tank configuration reduces floor space requirements while providing excellent condensate separation and air storage.
Sound Reduction Package
Acoustic enclosures and vibration isolation systems reduce operating noise levels for improved workplace environment and compliance.
Control System Features
Auto Dual Control
Automatically switches between load/unload and modulation control for maximum energy efficiency across all operating conditions.
Remote Monitoring
Ethernet and Modbus connectivity enables remote monitoring, control, and integration with building management systems.
Predictive Maintenance
Monitors operating parameters and provides alerts for maintenance needs before failures occur, reducing downtime.
Multi-Compressor Control
Coordinates multiple compressors for optimal system efficiency, load sharing, and sequenced operation.
Data Logging
Stores operational data for performance analysis, energy consumption tracking, and maintenance history.
Safety Shutdowns
Multiple safety shutdowns protect against high temperature, low oil pressure, motor overload, and other fault conditions.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor won't start | Power issue, pressure switch fault, thermal overload | Check power supply, verify pressure switch settings, reset overloads |
| Low pressure output | Intake filter clogged, leaking system, worn valves | Clean/replace intake filter, check for air leaks, inspect valves |
| Excessive noise/vibration | Loose mounting, worn bearings, improper foundation | Tighten mounting bolts, check bearings, verify foundation |
| High operating temperature | Dirty cooler, low oil level, ambient temperature high | Clean cooler fins, check oil level, improve ventilation |
| Excessive oil consumption | Worn piston rings, overfilled oil, leaking seals | Check compression, verify oil level, inspect seals |
| Frequent cycling | Air leaks, undersized receiver, incorrect pressure settings | Locate and repair leaks, check tank size, adjust pressure switch |
Error Codes
- E01: High temperature shutdown - Check cooling system and oil level
- E02: Low oil pressure - Check oil level and pressure switch
- E03: Motor overload - Check electrical connections and load
- E04: Phase loss/sequence - Check power supply phase rotation
- E05: Sensor failure - Check temperature/pressure sensors
- E06: Communication error - Check controller connections
- E07: High pressure shutdown - Check pressure switch and relief valve
- E08: Low pressure shutdown - Check intake and system pressure
Manual Downloads
QT Series Rotary Screw Compressors
QT-7.5
7.5 HP Rotary Screw
QT-25
25 HP Rotary Screw
QT-60
60 HP Rotary Screw
QT-100
100 HP Rotary Screw
QGS Series Reciprocating Compressors
QGS-5
5 HP Two-Stage
QGS-10
10 HP Two-Stage
QGS-20
20 HP Two-Stage
QGS-30
30 HP Two-Stage
Popular Industrial Models
QR-25
25 HP Rotary
QP-15
15 HP Portable
QT-200
200 HP Industrial
QSI-40
40 HP Silent Series