Snap-on Air Compressor

User Manual & Installation Guide

Industrial Grade Compressor

Installation Guide

Tools Needed:

  • Adjustable wrench set
  • Pipe thread sealant
  • Air pressure gauge
  • Level
  • Screwdrivers (flat and Phillips)
  • Teflon tape

Step-by-Step Installation

  1. Choose Installation Location: Select a clean, dry, well-ventilated area with adequate space for maintenance access and proper air circulation.
  2. Prepare Foundation: Ensure a solid, level concrete foundation that can support the compressor's weight and vibration.
  3. Electrical Connection: Connect to appropriate power supply (see specifications). All electrical work must comply with local codes.
  4. Air System Setup: Install proper air filtration, regulators, and lubricators in the air line system.
  5. Drain Installation: Connect condensate drain line to proper drainage system according to local regulations.
  6. Pressure Testing: Perform initial pressure test without load to check for leaks in connections.
  7. Initial Startup: Follow startup procedure in manual, checking oil levels and belt tension before operation.
Warning: Installation must be performed by qualified personnel. Improper installation can cause equipment failure, injury, or void warranty.

Specifications

Model Series SCP185G
Type Two-Stage Industrial Air Compressor
Horsepower 5 HP
Tank Capacity 80 Gallon Vertical
Maximum Pressure 175 PSI
CFM at 90 PSI 18.5 CFM
CFM at 175 PSI 16.2 CFM
Motor Type TEFC (Totally Enclosed Fan Cooled)
Power Requirements 230V, Single Phase, 60Hz, 24A
Pump RPM 1020 RPM
Noise Level 78 dB at 1 meter
Dimensions (HxWxD) 72 x 30 x 30 inches
Weight 425 lbs

Warranty Information

  • Full Warranty: 2 years parts and labor
  • Pump Warranty: 5 years on compressor pump
  • Tank Warranty: Lifetime on ASME certified tank
  • Additional Coverage: Optional extended service plans available

For warranty service, contact Snap-on Customer Service at 1-877-762-7662 or visit Snap-on.com

Key Features

Two-Stage Pump Design

Advanced two-stage compression provides higher efficiency, cooler operation, and longer pump life compared to single-stage compressors.

ASME Certified Tank

Heavy-duty 80-gallon ASME certified air tank with lifetime warranty, built to withstand industrial use and pressure cycling.

Magnetic Starter

Industrial-grade magnetic starter with overload protection ensures reliable motor starting and protection against voltage fluctuations.

Pressure Control System

Precision pressure switch with automatic shut-off and adjustable cut-in/cut-out pressures for optimal performance.

Thermal Overload Protection

Built-in thermal overload protection prevents motor damage from overheating during extended operation.

Low Oil Shutdown

Automatic shutdown system activates when oil levels drop below safe operating limits, preventing pump damage.

Performance Specifications

Air Delivery

18.5 CFM at 90 PSI for continuous tool operation

Duty Cycle

100% duty cycle capable of continuous operation

Recovery Time

Full tank recovery from 90 to 175 PSI in 2.5 minutes

Oil Capacity

64 oz synthetic compressor oil capacity

Belt Drive

Dual V-belt drive system for smooth power transmission

Cooling System

Large finned intercooler and aftercooler for efficient heat dissipation

Troubleshooting

Problem Possible Cause Solution
Compressor won't start Power issue, pressure switch fault, thermal overload tripped Check power supply, reset overload, inspect pressure switch
Low air pressure output Air leaks, worn valves, incorrect belt tension Check for leaks, inspect valves, adjust belt tension
Excessive noise/vibration Loose mounting, worn bearings, piston slap Tighten mounting bolts, check bearings, inspect pistons
Overheating Dirty cooling fins, low oil, restricted ventilation Clean cooling fins, check oil level, improve ventilation
Oil in air lines Worn piston rings, overfilled oil, faulty separator Check piston rings, adjust oil level, replace separator
Frequent cycling Air leaks, large demand, faulty check valve Locate and repair leaks, check system demand, replace check valve

Error Codes & Indicators

  • Red Light - Thermal Overload: Motor overheated - Allow to cool, check ventilation
  • Yellow Light - Low Oil: Oil level below minimum - Check and add oil immediately
  • Flashing Green - Pressure Switch Error: Pressure switch malfunction - Inspect and replace if needed
  • Continuous Beep - High Temperature: System overheating - Shut down and investigate cause
  • Intermittent Beep - Maintenance Due: Scheduled maintenance required - Perform oil change and inspection
  • No Power - Circuit Breaker: Electrical issue - Check breaker and wiring connections

Manual Downloads

Current Model Manuals

SCP185G

5HP 80-Gallon Two-Stage

SCP245G

7.5HP 80-Gallon Industrial

SCP605G

10HP 120-Gallon Commercial

SCP80V

3HP 60-Gallon Vertical

Popular Previous Models

SCP707V

7.5HP 80-Gallon Vertical

SCP60V

5HP 60-Gallon Single Stage

SCP40H

3HP 30-Gallon Horizontal

SCP20P

2HP 20-Gallon Portable

Note: For models not listed here, please visit the Snap-on Support Website for complete documentation and technical specifications.